The problem is that ORD685B only requires three parameters, two of which
are data structures. If it were me, I'd create a program to load the
required fields just like ORD685D does, then use that as your job schedule
program. I've had to do several programs to mimic the screen entries, and
as long as you don't have the security calls, which I didn't see in
ORD685B, you shouldn't have to worry about calling SYS664 in a CL.
Rick Folsom
Yupo Corporation America
757-819-9230
Lat - Sandy Sever
<sandys@xxxxxxxxx To: bpcs-l@xxxxxxxxxxxx
> cc:
Sent by: Subject: ** Schedule Order Hold
Report to
bpcs-l-bounces@mi Print...**
drange.com
07/07/2004 11:59
AM
Please respond to
"SSA's BPCS ERP
System"
Hello,
We would like to automatically print the
Order Hold Report every night using IBM's
job scheduler.
I added a job to the scheduler and tested,
but receive and error message when calling the
program ORD685B or ORD685D:
Error message CPF4101 appeared during OPEN (C S D F).
I then changed and added parameters in the job
scheduler, but still
am receiving errors, see below:
Command to run . . . . . . . . . CALL PGM(B61O/ORD685D) PARM('00 99
000000 99
9999 000000 999999 000000 999999 0')
Then I tried from the command line:
Program . . . . . . . . . . . . > ORD685D Name
Library . . . . . . . . . . . > B61O Name, *LIBL, *CURLIB
Parameters . . . . . . . . . . . > '00 99 000000 999999 000000 999999
000000 99
9999 0'
Message . . . . : Parameters passed on CALL do not match those required.
Cause . . . . . : The parameters passed on the CALL command do not match
the
parameters required by program ORD685D in library B61O. Correct program
not
found or correct parameters not passed. The number of parameters or the
type
of parameters passed on the CALL command must match those expected by
the
program called.
What do I have to do to get this report to run (using the defaults) in the
job scheduler?
Defaults:
Type desired selection criteria, press Enter.
Company To 99
Customer Number To 999999
Request Date 0/00/00 To 99/99/99
Order Number To 999999
Run Time Parameter 1 (0=Interactive 1=Batch)
Any suggestions, will get greatly appreciated...
Thanks,
Sandy
_______________________________________________
This is the SSA's BPCS ERP System (BPCS-L) mailing list
To post a message email: BPCS-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/bpcs-l
or email: BPCS-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/bpcs-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.