Paul
Check the list archives and also the infor support site for the specific
BMR numbers , but in addition to the BMR for CEA, there is a BMR for SQL
that MUST be applied for V6 releases of BPCS. It's pretty simple to
enter, but failure to use it will cause some significant performance
issues with some of the AS/Set programs that use imbedded SQL.
PC
"Paul Scyner" <PScyner@xxxxxxxxxxxxxxxxx>
Sent by: bpcs-l-bounces+phil.catlin=formica.com@xxxxxxxxxxxx
05/23/2007 01:52 PM
Please respond to
"SSA's BPCS ERP System" <bpcs-l@xxxxxxxxxxxx>
To
"SSA's BPCS ERP System" <bpcs-l@xxxxxxxxxxxx>
cc
Subject
Re: [BPCS-L] BPCS V6 and OS/400 V5R3
Ok, thanks for your help with this.
Regards,
Paul
-----Original Message-----
From: Davide Roveda [
mailto:davide.roveda@xxxxxxxxx]
Sent: 23 May 2007 16:30
To: SSA's BPCS ERP System
Subject: Re: [BPCS-L] BPCS V6 and OS/400 V5R3
Confirmed.
You are affected, as you use CEA.
Regards.
Davide
-----Original Message-----
From: bpcs-l-bounces+davide.roveda=infor.com@xxxxxxxxxxxx
[
mailto:bpcs-l-bounces+davide.roveda=infor.com@xxxxxxxxxxxx] On Behalf Of
Paul Scyner
Sent: mercoledì 23 maggio 2007 17.18
To: SSA's BPCS ERP System
Subject: Re: [BPCS-L] BPCS V6 and OS/400 V5R3
Currently we're using COM and CEA, but the rest is mixed mode, i.e. green
screen emulation using client access.
Sorry for asking the daft question, but is client access ok or is it also
affected by this OS issue?
Thanks,
Paul
-----Original Message-----
From: Davide Roveda [
mailto:davide.roveda@xxxxxxxxx]
Sent: 23 May 2007 16:10
To: SSA's BPCS ERP System
Subject: Re: [BPCS-L] BPCS V6 and OS/400 V5R3
Hello
Yes, you have to apply that if you use V6 on V5R3 (and higher) with BPCS
Client server and/or CEA.
That because the deamon server for communication use an IBM communication
API that has been changed for nr of parameter.
That BMR contains the BPCS server part to allow communication with new
parm list.
If you use mix mode only, you do not need.
Thanks
Davide
-----Original Message-----
From: bpcs-l-bounces+davide.roveda=infor.com@xxxxxxxxxxxx
[
mailto:bpcs-l-bounces+davide.roveda=infor.com@xxxxxxxxxxxx] On Behalf Of
Paul Scyner
Sent: mercoledì 23 maggio 2007 17.00
To: bpcs-l@xxxxxxxxxxxx
Subject: [BPCS-L] BPCS V6 and OS/400 V5R3
Importance: High
Hi all,
We're planning on moving to a new iseries later this year and I've heard
that a BMR (No.67665) has to be applied to BPCS as it causes problems
with the login process.
It doesn't affect green screen, but does affect client/server gui and
web interfaces.
Can anyone shed any light on this?
Thanks,
Paul
This e-mail and any attachment, is confidential. If you received it in
error, please delete it from your system, do not use or disclose the
information in any way, and notify me immediately. The contents of this
message may contain personal views which are not the views of Daiwa Sports
Limited, unless specifically stated.
SAVE PAPER - Please do not print this e-mail unless absolutely necessary
As an Amazon Associate we earn from qualifying purchases.