-----Original Message-----
From: Weatherly, Howard <hweatherly@dlis.dla.mil>
To: 'COBOL400-L@midrange.com' <COBOL400-L@midrange.com>
Date: Monday, July 23, 2001 11:05 AM
Subject: RE: System API QlnDumpCobol
>Great the NOMONOPRC works fine on the PROCESS statement! It recognizes
lower
>case across the SQL pre-compiler. Also in answer to my other question it
>does not work doing:
>
>1 CALL-NAME pic x(12) value "QlnDumpCobol".
>Call CALL-NAME .....
>
>It fails with the message Non numeric literal required
>
Yeah, Howard, unfortunately, Procedure calls must be done static, not
dynamic. The best you can do is to use procedure pointers.
===========================================================
R. Bruce Hoffman, Jr.
-- IBM Certified Specialist - AS/400 Administrator
-- IBM Certified Specialist - RPG IV Developer
"America is the land that fought for freedom and then
began passing laws to get rid of it."
- Alfred E. Neuman
+---
| This is the COBOL/400 Mailing List!
| To submit a new message, send your mail to COBOL400-L@midrange.com.
| To subscribe to this list send email to COBOL400-L-SUB@midrange.com.
| To unsubscribe from this list send email to COBOL400-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---END
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.