DESCRIPTION OF PROBLEM FIXED FOR APAR MA24927 :
-----------------------------------------------
The values returned for the following programming interfaces may
be incorrect:
MATRMD MI
Interactive Utilization Data Option Hex 1E -
Offset Hex 10 Interactive threshold
Offset Hex 12 Interactive limit
QYHCHCOP -
CommmercialProcessingWorkloadTotal
CommercialProcessingWorkloadInteractive
CORRECTION FOR APAR MA24927 :
-----------------------------
The problem will be fixed. Correct CPW numbers will be returned.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].