|
x-post ----- Original Message ----- From: vsmanju <vsmanju@xxxxxxxxxxx> To: <mi400@xxxxxxxxxxxx> Sent: Tuesday, July 22, 2003 10:30 PM Subject: [MI400] Problem in syncronising AS40o time to windows 2000 server. > Hi, > > I have a problem in SNTP Client, I am trying to sync the time > with Windows2000 server. I tried changing the QUTCOFFSET system value > and then starting the TCPSVR *NTP, and also tried changing CHGNTPA > values. But the same error is coming showing the time difference of > UTC. Please advice as to how I can proceed to Synchronize the time > between windows2000 server and AS400. > > Thanking you in advance > > > Regards > > Manju > > 1. On server side the windows time services is enabled on the the > server. > > 2. On AS400 side > > AS400 version V5R1 model 720 and the machines are in different segments > but on the same network. > ------------------------------------------------------------------------ > --------------------- > CHGNTPA IS > > Remote system . . . . . . . . . 'servername.domain.com' > > Autostart . . . . . . . . . . . *YES *SAME, *NO, *YES > Poll interval . . . . . . . . . 60 1-1440 minutes, *SAME > Minimum adjustment . . . . . . . 300 20-300000 > milliseconds... > Maximum adjustment . . . . . . . 20 5-30 minutes, *SAME > Activity log . . . . . . . . . . *POLL *SAME, *NONE, *CHANGE, > *POLL > > ------------------------------------------------------------------------ > ----------------------- > > Display System Value > > System value . . . . . : QUTCOFFSET > Description . . . . . : Coordinated universal time offset > > > Offset . . . . . . . . : -00:00 -24:00 to +24:00 > ------------------------------------------------------------------------ > ---------------------- > > When I start the TCPSVR *NTP I am getting the following error message > please help. > > ------------------------------------------------------------------------ > ------------------------- > Additional Message Information > Message ID . . . . . . : TCP9138 Severity . . . . . . . : 40 > Message type . . . . . : Diagnostic > Date sent . . . . . . : 07/22/03 Time sent . . . . . . : 12:57:19 > Message . . . . : The maximum adjustment threshold for the SNTP Client > has > been exceeded, SNTP clock is not set. > Cause . . . . . : The software clock UTC time is 07/22/03 12:57:18. The > NTP > server UTC time is 07/22/03 7:33:39. The difference in time between the > 2 > clocks is -323 minutes. The maximum allowed time adjustment is 30 > minutes. > Recovery . . . : If the time difference between the 2 clocks is less > than > 30 minutes, Use CHGNTPA to set the MAXADJUST to a value greater than the > difference between the 2 clocks. If the time difference between the 2 > clocks > is greater than 30 minutes, use WRKSYSVAL to make sure QTIME and QDATE > are > set correctly. Make sure QUTCOFFSET is also set correctly. Daylight > savings time changes may cause the values to be incorrectly set. > > _______________________________________________ > This is the MI Programming on the AS400 / iSeries (MI400) mailing list > To post a message email: MI400@xxxxxxxxxxxx > To subscribe, unsubscribe, or change list options, > visit: http://lists.midrange.com/mailman/listinfo/mi400 > or email: MI400-request@xxxxxxxxxxxx > Before posting, please take a moment to review the archives > at http://archive.midrange.com/mi400. >
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.