>Two quick questions:
>
>1. At a site with a 5394 remote workstation controller, how do I
>assign twinax addresses for ports 1+ in CA95 with Netsoft router (port
>0 is devices 0-6, port 1 is 7-0D, etc)? For a person on port 1, switch
>9, do I use 2 for the twinax address? This seems to be correct, just
>want to verify. (In DOS PCS the line with the switch setting would say
>9, which also matches the device description on the 400.)
>
>2. Also with CA95 and 5394, I'm getting an error message along the
>lines of "AS400 license". It's error CBW06 I think. The help says the
>system name is incorrect or other problem, but everything's set up
>correctly. Any ideas?
>
>Only 3 people are using Win95+CA95 at this location. One set up
>without problems. Now this. (Third person out of office, can't do
>yet.)
>
>TIA,
>Loyd Goodbar
Addressing for a 5394 controller is as follows:
Twinax
Port \ Address 0 1 2 3 4 5 6
0 00 01 02 03 04 05 06
1 07 08 09 0A 0B 0C 0D
2 0E 0F 10 11 12 13 14
3 15 16 17 18 19 1A 1B <--- only on a 5294
Your example, Address 09 on Port 1 is switch setting 02 on the device.
--Paul E Musselman
PaulMmn@ix.netcom.com
+---
| This is the Midrange System Mailing List!
| To submit a new message, send your mail to "MIDRANGE-L@midrange.com".
| To unsubscribe from this list send email to MAJORDOMO@midrange.com
| and specify 'unsubscribe MIDRANGE-L' in the body of your message.
| Questions should be directed to the list owner/operator: david@midrange.com
+---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.