FYI: An IBM APAR that may be of interest. The fix mentioned MAY or MAY
NOT solve the problem you are having. It didn't help in my situation
for the Windows95/NT Client, although the option to turn off address
checking in the Windows 3.1 Client (file PCSTDLC.DAT) did solve the
problem for Windows 3.1 at my site.
Item SA66465
APAR Identifier ...... SA66465 Last Changed..97/08/12
CA400WINOPT-COMM-NETSOFT-TDLC-RC=000000FD UNPREDICTABLE RESULTS
WITH TWINAX HUBS AND UTP
Symptom ...... UR UNPRED Status ........... CLOSED PRS
Severity ................... 3 Date Closed ......... 97/08/12
Component .......... 5763XD100 Duplicate of ........
Reported Release ......... 312 Fixed Release ............
Component Name 5763 CA400 WIN Special Notice
Current Target Date ..97/08/20 Flags
SCP ...................
Platform ............
Status Detail: APARCLOSURE - APAR is being closed.
PE PTF List:
PTF List:
Parent APAR:
Child APAR list:
ERROR DESCRIPTION:
If using:
A. Client Access for Windows 95/NT Client (V3R1M0, V3R1M1
and V3R1M2) -and-
B. Running on Windows 95 PC -and-
C. Using the NetSoft Router, Twinax link type and the VxD adap
adapter handlers (PDLWATV.VXD and VDNSWQ.VXD) -and-
D. With hardware connectivity to AS/400 via Unshielded Twisted
Pair (specifically, Unshielded Twisted Pair cabling with
baluns and some type of twinax patch panel or hub)
Unpredictable results may occur. This problem occurs on all PC
adapters, but is most prevalent on PCI bus types.
When making this connection, the Netsoft Router's Event
Event Log viewer may report one or more of the following
messages:
TWINAX-16 (any return code), or
RT000B return code 1C
The Twinax Adapter Handler pop up box may display 'Open
Twinax station failed and one of the following return codes:
000000FB or
000000FC or
000000FD.
LOCAL FIX:
Bypass the hub using real twinax cable.
PROBLEM SUMMARY:
If using:
A. Client Access for Windows 95 (V3R1M0, V3R1M1 or V3R1M2)
-and-
B. Running on Windows 95 PC
-and-
C. Using the NetSoft Router, Twinax link type and the VxD
adapter handlers (PDLWATV.VXD and VDNSWQ.VXD)
-and-
D. With hardware connectivity to AS/400 via Unshielded Twisted
Pair (specifically, Unshielded Twisted Pair cabling with
baluns and some type of twinax patch panel or hub)
Unpredictable results may occur. This problem occurs on all PC
Twianx adapters, but is most prevalent on PCI bus types.
When making this connection, the Netsoft Router's Event
Event Log viewer may report one or more of the following
messages:
TWINAX-16 (any return code), or
RT000B return code 1C
The Twinax Adapter Handler pop up box may display 'Open
Twinax station failed' and one of the following return codes:
000000FB or
000000FC or
000000FD.
PROBLEM CONCLUSION:
Per II10307, the return codes indicate a polling or address
checking problem. Client Access was written to the original
Twinax specification and is working as designed.
Since the connection will depend heavily on the hardware being
used, Client Access cannot guarantee that it will work on all
hardware (especially hardware that changes the definition of
Polling and Address Checking). Newer twinax hardware (patch
panels etc.) change the polling and address checking.
The current Adapter Handlers for use in Windows 95 will not be
changed to support these various definitions. But, Client
Access is working on replacing these adapter handlers in future
releases with a newer adapter handler that should be more
tolerant of the different hardware specifications.
Until that newer version is released, a version of the current
VxD adapter handler will be made available that turns off
address checking and waits longer for Polls. Using this version
of the VxD adapter handler could result in Workstation Address
conflicts. In addition, this version of the VxD Adaptor handler
still may not resolve the problem. This version is available
"AS-IS" and may not be serviced nor updated. Obtain this VxD
from the following internet FTP site: ftp.software.ibm.com in
directory
/as400/products/clientaccess/win32/v3r1m2/files/twinax
The files are PDLWATWV.VXD and README.TXT.
Local Fix Options: 1. Use VxD adapter which turns off address
checking 2. Use real Twinax cabling. 3. Wait for future Mod
level of CA/400 for Windows 95/NT
client which will include support for UTP/Hubs
TEMPORARY FIX:
COMMENTS:
MODULES/MACROS: NONE
SRLS: NONE
RTN CODES:
CIRCUMVENTION:
Use real Twinax cabling and no Hubs.
CA400PIN
MESSAGE TO SUBMITTER:
... Neil Palmer AS/400~~~~~
... NxTrend Technology - Canada ____________ ___ ~
... Thornhill, Ontario, Canada |OOOOOOOOOO| ________ o|__||=
... Phone: (905) 731-9000 x238 |__________|_|______|_|______)
... Cell.: (416) 565-1682 x238 oo oo oo oo OOOo=o\
... Fax: (905) 731-9202 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
... mailto:NPalmer@NxTrend.com http://www.NxTrend.com
+---
| This is the Midrange System Mailing List!
| To submit a new message, send your mail to "MIDRANGE-L@midrange.com".
| To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.