>An index build is accomplished by one machine instruction, so it cannot be
>interrupted. Even a normal ENDJOB will not kill it, the index build will
>complete, and then the job will die. You can do an ENDJOBABN, but this has
>to be initiated 10 minutes after a preceding ENDJOB, and I'm not positive
>that this will kill it either.
You could, detach the UPS and then "Pull the Plug" ... :)
Kenneth
--
********************************
Kenneth E. Graap
IBM Certified Specialist
AS/400 Professional
System Administrator
NW Natural - Information Services
System Services
503 226 4211 X5537
FAX 603 849 0591
keg@nwnatural.com
********************************
-----Original Message-----
From: Al Barsa, Jr. [mailto:barsa2@ibm.net]
Sent: Thursday, July 01, 1999 1:34 PM
To: MIDRANGE-L@midrange.com
Subject: Re: Cancelling an index build
+---
| This is the Midrange System Mailing List!
| To submit a new message, send your mail to MIDRANGE-L@midrange.com.
| To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com.
| To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].