|
For our weekly backup program, we want to end the system to a restricted condition. The program works great when run from a command line, but bombs when run from the internal job scheduler (WRKJOBSCDE) or the advanced job scheduler (GO JS). The error message I'm getting is: 4800 - ENDSBS SBS(*ALL) OPTION(*IMMED) CPF1052 Escape 40 ENDSBS *ALL not allowed in current environment. ENDSBS *ALL is not allowed only from an interactive job that is started from a *SIGNON workstation entry in the controlling subsystem. ENDSBS *ALL is not allowed from a target pass-through job. The job is submitted to the QCTL subsystem, running as user QSYSOPR. Is there an easy way around this? Thanks! Loyd -- Loyd Goodbar Programmer/Analyst BorgWarner Incorporated Air/Fluid Systems, Water Valley, MS +--- | This is the Midrange System Mailing List! | To submit a new message, send your mail to MIDRANGE-L@midrange.com. | To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com. | To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.