For our weekly backup program, we want to end the system to a restricted
condition. The program works great when run from a command line, but bombs
when run from the internal job scheduler (WRKJOBSCDE) or the advanced job
scheduler (GO JS). The error message I'm getting is:
4800 - ENDSBS SBS(*ALL) OPTION(*IMMED)
CPF1052 Escape 40 ENDSBS *ALL not allowed in current environment.
        ENDSBS *ALL is not allowed only from an interactive job that is
started from a *SIGNON workstation entry in the controlling subsystem.
ENDSBS *ALL is not allowed from a target pass-through job.
The job is submitted to the QCTL subsystem, running as user QSYSOPR.
Is there an easy way around this?
Thanks!
Loyd
--
Loyd Goodbar
Programmer/Analyst
BorgWarner Incorporated
Air/Fluid Systems, Water Valley, MS
+---
| This is the Midrange System Mailing List!
| To submit a new message, send your mail to MIDRANGE-L@midrange.com.
| To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com.
| To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].