Hi Scott,
Thanks for the reply.  The QSQSRVR jobs all have the same messages, which do
not seem related:
---
ACGDTA for 000786/QUSER/QSQSRVR not journaled; reason 1.
     [-- 1-The accounting level system value (QACGLVL) indicated that this
level of resource accounting was not to be done when the job entered the
system.]
Printer device PRT01 not found.
Job changed successfully; however errors occurred.
---
QSECOFR is enabled and its password is not expired.
Where do I define Endpoint Systems?  If, as I suspect, it's within
Management Central, then I'm in a catch-22 situation, since I can't get Mgtc
started to connect to my Central System.
Peter Dow
Dow Software Services, Inc.
909 793-9050 voice
909 793-4480 fax
909 522-3214 cell
From: "Ingvaldson, Scott"
> Try checking the QSQSRVR jobs being used by QYPSJSVR for errors.  Also the
> QSECOFR password cannot be expired (even if the profile is enabled) for
the
> QYPSJSVR job to run.  Verify that you do not have your central system
> defined by a different name (or twice) under Endpoint Systems.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].