any chance the system is LPAR'd?? If so I have seen where the system will not vary lines/controllers/devices if there are resources the used to be assigned to the primary that are not "there" anymore. I mean they show up as unknown devices in the hardware device manager in SST. ---------------------------- Bryan Dietz Aktion Associates midrange-l-bounces@xxxxxxxxxxxx wrote on 04/20/2004 04:11:09 AM: > Hello, > > we have two twinax controllers (CTL01 and CTL02) on our 810 with V5R2. > > During IPL, I will get a message like "Vary on at IPL for CTL01 finished". > The same message for CTL02 will come up to 24 hours later? > > Up to yesterday, this didn't give a problem. But yesterday morning, I > found that all twx devices on CTL02 were varied off! > When I varied them on manually, I finally got the above message. > > Both controllers are configured to vary on at IPL. > > My guess is this is happening since our V5R2 upgrade in December 2003. > > Any ideas what is going on here? > > Regards, > > Oliver >
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].