Interesting... I tried this, first on our V5R1 system and got this:
....+....1....+....2....+....3....+....4....+.
MYTEXT MYNBR
1 1/2 1
******** End of data ********
Next, I tried it on our V5R3 system and got this:
....+....1....+....2....+....3....+....4....+.
MYTEXT MYNBR
1 1/2"" of stuff 1
******** End of data ********
I copied and pasted the commands from one screen to another. Both systems
got the latest PTF's in January so they shouldn't be too far off.
Dave Parnin
Nishikawa Standard Company
Topeka, IN 46571
daparnin@xxxxxxxxxxxxxx
rob@xxxxxxxxx
Sent by: To: Midrange Systems
Technical Discussion
midrange-l-bounces@m <midrange-l@xxxxxxxxxxxx>
idrange.com cc:
Subject: Re: CPYFRMIMPF and
double delimiters
04/29/2005 03:15 PM
Please respond to
Midrange Systems
Technical Discussion
V5R3
dspf rob/borg.txt
....+....1....+....2....+....3
************Beginning of data
"1 1/2"" of stuff",1
************End of Data******
CREATE TABLE ROB/BORG
(MYTEXT CHAR (30 ) NOT NULL WITH DEFAULT,
MYNBR INT NOT NULL WITH DEFAULT)
CPYFRMIMPF FROMSTMF('/rob/borg.txt')
TOFILE(ROB/BORG)
RCDDLM(*CRLF)
select * from rob/borg
....+....1....+....2....+....3....+....4....+.
MYTEXT MYNBR
1 1/2"" of stuff 1
******** End of data ********
Rob Berendt
--
Group Dekko Services, LLC
Dept 01.073
PO Box 2000
Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
"Goodbar, Loyd (ETS - Water Valley)" <LGoodbar@xxxxxxxxxxxxxx>
Sent by: midrange-l-bounces@xxxxxxxxxxxx
04/29/2005 02:58 PM
Please respond to
Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
To
Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
cc
Subject
CPYFRMIMPF and double delimiters
We're having an issue with CPYFRMIMPF, on V5R2. When we receive character
data such as "1 1/2"" 90 DEG ELL PVC SCH 80", only "1 1/2" appears in the
database file. I thought there was a PTF to fix this. This is a vendor's
standard extract file that we can't touch (remote SQL server system we
don't
have access to). Any ideas?
Thanks,
Loyd
Loyd Goodbar
Senior programmer/analyst
BorgWarner
E/TS Water Valley
662-473-5713
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.