Eric - I am aware of that problem, and "think" I did wait. I know system will issue error (with retry) if it thinks a volume not loaded. It actually took a few minutes to realize there was a pattern to the problem, a loop repeating over & over. Opening & closing cd drive door somehow got it out of the loop. It was interesting that cume had the problem, but not the groups after the cume.
I've got a v5r3 to v5r4 to do in next few days. Will watch it better.

jim franz

----- Original Message ----- From: "DeLong, Eric" <EDeLong@xxxxxxxxxxxxxxx>
To: "Midrange Systems Technical Discussion" <midrange-l@xxxxxxxxxxxx>
Sent: Tuesday, May 30, 2006 3:46 PM
Subject: RE: completed v5r2 to v5r4


Jim,

I did V5R1 to V5R3 a few weeks ago, and was instructed (by the admin) to wait for the CD light to flash when loading a new CD. It seems there's a few seconds delay after inserting a new CD before it's mounted. We just waited for ten seconds or so after inserting the disc.

Eric DeLong
Sally Beauty Company
MIS-Project Manager (BSG)
940-297-2863 or ext. 1863



-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx]On Behalf Of Jim Franz
Sent: Monday, May 29, 2006 1:04 PM
To: MIDRANGE-L@xxxxxxxxxxxx
Subject: completed v5r2 to v5r4


just completed a v5r2 to v5r4 upgrade.
Not too bad. low end Model 800 35 gig disk, twinax console (only twinax left) Was at 64% and went to 86% - not totally unexpected and they are now weeding out old stuff.
Did find some mapped drives were storing music files....

It's a pain to work a conversion from a laptop on the Info Center website.
Did the prebuild of the time zone data area & that worked well.
Did the step to allocate space - that took it from 64% to 71%

Did the pre upgrade ptf's - info center said "maybe an ipl...." - well
1st pass 2 ptfs did not apply, and text said the mfxxxx had to be perm apply for the other to apply - set the mf to perm apply, ipl'd and when done both had applied ok.

All the pre conversion stuff took 3 hours to get thru, going from web page to system console and multiple ipls. (console & system in a glass cubicle with no network cable for the laptop... Release upgrade took 5 hours. with 3 hours spent on first few cd's, then it sucked in remaining.

Did find BP or IBM failed to ship product that were in existing system - Crypto Acc Provider
but they are not using.

My one big problem - applied cume after release loaded, before inzsys as Info Center advised. 1st cd went in fine, 2nd cd went in, and looked like in a loop - flurry of activity, cd rom light not on, screen not showing next cd was in... over & over (10 minutes....) so i opened cd drive, closed again...
and it worked. Did same to 3rd cd and 4th. but not after that..

Was starting to upgrade clients to new iSeries Access V5R4, but 2nd pc started freezing up so we stopped. Its a new high poweered HP laptop, and I seem to remember a prev thread about connection problems. Will investigate later.

jim franz
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.



--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.




As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.