Device PRT04M no longer communicating.
Device PRT03 no longer communicating. (This is the last message in the log)
Error occurred while processing object QSZPAVLI in library QUSRSYS.(This is the 
first msg before ipl starting)
Unattended IPL in progress after abnormal system end.              
nothing is there in WRKPRB.
Thanks.
Bob.D
----- Original Message ----
From: "smorrison@xxxxxxxxxxxxxxxxxxx" <smorrison@xxxxxxxxxxxxxxxxxxx>
To: Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
Sent: Monday, April 23, 2007 11:18:50 AM
Subject: Re: IPL status...
Well, if it isn't a DASD overflow problem, do a DSPLOG QHST. Scroll 
backward, and see if you can see a problem there. Check the entries before 
your IPL this morning, and see if you can find something. Also try the 
WRKPRB command, and see if there are any problems there.
Steven Morrison
Fidelity Express 
903-885-1283  ext. 479
Bob David <bob_wkot@xxxxxxxxx> 
Sent by: midrange-l-bounces@xxxxxxxxxxxx
04/23/2007 10:04 AM
Please respond to
Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
To
Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
cc
Subject
Re: IPL status...
its only around 50% of ASP used.
----- Original Message ----
From: "smorrison@xxxxxxxxxxxxxxxxxxx" <smorrison@xxxxxxxxxxxxxxxxxxx>
To: Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
Sent: Monday, April 23, 2007 9:57:15 AM
Subject: Re: IPL status...
                       Additional Message Information 
Message ID . . . . . . :   CPI091D 
Date sent  . . . . . . :   04/23/07      Time sent  . . . . . . : 07:48:19 
   8 - Some data could not be written to auxiliary storage while the 
system 
 was ending. 
   9 - Some data could not be written to auxiliary storage since the 
previous
 IPL. 
My first guess is that you filled up your disk. Do you have anyone 
experienced in systems administration?
If you have the system restarted, type WRKSYSSTS from a command line, and 
see what your '% of system ASP used' is, in the upper right section of the 
screen. if it's 90% or above you have a problem because the systems stops 
communications as the DASD gets above 90%. 