Device PRT04M no longer communicating.
Device PRT03 no longer communicating. (This is the last message in the log)
Error occurred while processing object QSZPAVLI in library QUSRSYS.(This is the
first msg before ipl starting)
Unattended IPL in progress after abnormal system end.
nothing is there in WRKPRB.
Thanks.
Bob.D
----- Original Message ----
From: "smorrison@xxxxxxxxxxxxxxxxxxx" <smorrison@xxxxxxxxxxxxxxxxxxx>
To: Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
Sent: Monday, April 23, 2007 11:18:50 AM
Subject: Re: IPL status...
Well, if it isn't a DASD overflow problem, do a DSPLOG QHST. Scroll
backward, and see if you can see a problem there. Check the entries before
your IPL this morning, and see if you can find something. Also try the
WRKPRB command, and see if there are any problems there.
Steven Morrison
Fidelity Express
903-885-1283 ext. 479
Bob David <bob_wkot@xxxxxxxxx>
Sent by: midrange-l-bounces@xxxxxxxxxxxx
04/23/2007 10:04 AM
Please respond to
Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
To
Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
cc
Subject
Re: IPL status...
its only around 50% of ASP used.
----- Original Message ----
From: "smorrison@xxxxxxxxxxxxxxxxxxx" <smorrison@xxxxxxxxxxxxxxxxxxx>
To: Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
Sent: Monday, April 23, 2007 9:57:15 AM
Subject: Re: IPL status...
Additional Message Information
Message ID . . . . . . : CPI091D
Date sent . . . . . . : 04/23/07 Time sent . . . . . . : 07:48:19
8 - Some data could not be written to auxiliary storage while the
system
was ending.
9 - Some data could not be written to auxiliary storage since the
previous
IPL.
My first guess is that you filled up your disk. Do you have anyone
experienced in systems administration?
If you have the system restarted, type WRKSYSSTS from a command line, and
see what your '% of system ASP used' is, in the upper right section of the
screen. if it's 90% or above you have a problem because the systems stops
communications as the DASD gets above 90%.
Steve
Steven Morrison
Fidelity Express
903-885-1283 ext. 479
As an Amazon Associate we earn from qualifying purchases.