Couple things off the top of my head.
Train the user to exit the SEU session using "FILE" at the command line.
You can put this process into a CL and process the exiting message EDT0229
"Member XXXX in file LIBR/SRCFILE changed with 999 records." To see if the
user messed anything up.
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[
mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Jonathan Mason
Sent: Thursday, June 28, 2007 5:57 AM
To: 'Midrange Systems Technical Discussion'
Subject: Locking down SEU exit parameters
Does anybody know if it is possible to lock down the parameters shown on the
SEU Exit screen?
I have a requirement where I need to invoke SEU so that the users can
perform some text editing on a specific TXT member and I am concerned that
the user may change the member name, source file or library when they exit
out of SEU.
Ideally I would like to be able to prevent the parameters from being
overridden (in a similar manner to command prompting using "?-" etc) or
alternatively find a means of identifying the source member, file and
library specified on the Exit screen.
I thought about using an exit program, but could only find QIBM_QSU_LCMD
which relates to SEU line commands.
Any ideas?
Thanks
Jonathan