There is now a parm on the PWRDWNSYS command, CONFIRM, that allows this. I
think this was added at V5R3. It defaults to Environment variable, which
the environment var isn't set itself by default. Therefore, you can either
change the environment varilable to *INTERACT or change the command default
for PWRDWNSYS command for the CONFIRM parameter and set that to *INTERACT.
Pete
Pete Massiello
www.itechsol.com
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Michael Rosinger
Sent: Friday, September 21, 2007 6:42 AM
To: midrange-l@xxxxxxxxxxxx
Subject: operators and PWRDWNSYS
List,
I am interested how other shops handle this issue. I want my operators to be
able to perform an IPL at times but I am reluctant to give them permissions
to execute PWRDWNSYS. The reason is concern that it will be accidental. If
you key the command without prompting it begins an immediate controlled
shutdown with no IPL.
Is there a way to have the system force a confirmation (i.e. a "are you
sure?" type message) if the command is issued with no prompting? A system
value perhaps that controls this?
Who has permissions to issue PWRDWNSYS in your shop?
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact