Its Hot swappable. He/she comes in, goes to SST, says he is doing
concurrent maintenance, and enters which drive, SST tells him remove the
drive, then insert new one, presses enter, and then goes back into work with
Disk units and rebuild the raid set.
It could take about 60 minutes to rebuild, and the system might be a
little slow during that time, but other then that you shouldn't miss a beat.
Pete
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Jerry Adams
Sent: Friday, September 28, 2007 2:55 PM
To: Midrange-L
Subject: Disk Failure
Unit 1 in our four disk set (Raid5) failed. The IBM CE called and is
bringing a replacement, but I've got a question or two before he arrives.
First, isn't unit 1 where the load source lives?
Second, are there any special steps in the recovery because of that?
Third, he said it was hot swappable. (I'm still going to kick everyone
off of the system, though.) Is it really that easy?
Thanks.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact