If it's a *PGM then reference the parameter with a MONMSG for MCH3601 immediately following the reference. If the MONMSG gets control then the parameter wasn't passed. For instance:
ChgVar Var(&Path) Value(&Path_In *TCat &Null)
MonMsg MsgID(MCH3601) Exec(Do)
RcvMsg MsgType(*Last)
SndPgmMsg Msg(&RqdParm) ToPgmQ(*Ext)
Return
EndDo
is a test for parameter &Path_In
Bruce
James Lampert <jamesl@xxxxxxxxxxxxxxxxx> wrote:
Is there a way for a CL program to verify that it actually received a
parameter it expects?
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact