Thanks as always, Rob.
So I have this:
System Unit 9406-270 FR01
Backplane 283E P19 DB1
Disk Unit * 6718-074 P06 D01
Disk Unit 6718-074 P08 D02
Disk Unit 6718-074 P11 D03
Disk Unit 6718-074 P10 D04
Disk Unit 6718-070 P09 D05
Disk Unit 6718-070 P20 D06
That's six drives in a RAID set. Works nicely, everybody is happy. But
from the way I read Larry's statement, if D01 goes, I'm SOL. Is the
better option to somehow mirror two of them for the load source and then
put the other four in a RAID set? I'd lose one drive of effective
space, or 20% of my total. And can this even be done without some
serious hoop jumping (i.e. reloading the system)?
Joe
STRSST
1. Start a service tool
7. Hardware service manager
1. Packaging hardware resources (systems, frames, cards,...)
9=Hardware contained within package (On various items until you see
something like)
Type- Resource
Description Model Name Location
Disk Expansion Unit 5787-001 FR10
Backplane 505C P144 P1
Disk Unit * 4328-070 P60 P1-D1
...
* - Indicates that this packaging hardware resource is the
load source disk unit or the IOP that the disk unit is
attached to.
Rob Berendt
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.