Elvis Budimlic wrote:
Google "trigger QWVRCSTK" and you'll get one possible solution.
Interesting, but I can't guarantee that QWVRCSTK will be available on
customer boxes (and it CERTAINLY isn't available on most of ours!)
But that did lead me to Richard Ecuyer's example from February 2006:
http://archive.midrange.com/midrange-l/200602/msg00666.html
The only problem with that is that it doesn't work: it climbs past the
caller, all the way to QUICMD, QUOCMD, or whatever. In the example, we have:
> D Pm_CSEntry S 10 Inz('*')
> D Pm_Counter S 9B 0
. . .
> c Eval pm_counter=5
which looks like it just climbs 5 levels back from the trigger itself.
Why 5 levels? Wouldn't it make more sense (as in the CL examples I
looked at that work on the same principle) to look for whatever called
QDBUDR or QDBPUT?
This mailing list archive is Copyright 1997-2026 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact
[javascript protected email address].