Rob,
I checked the security validation on the remote appn configuration and
it is set to *NO.
And I did get a CPF1269 on the local system with a Reason Code 1. But
I could not find what Reason Code 1 stands for.
I don't think this a common problem. We had all sorts of problems with
this remote system.
We even recreated the controlers and APPC devices.
The only thing that got it back to work is restarting SNADS on both
sides.
Le 21 Novembre, 2008 à 09:32, "Pascal Bellerose"
<pascal_bellerose@xxxxxxxxxxxx> a écrit :
Dear Midrange Experts,
We got a strange problem after a role-swap from our production system
to its backup system. This system is communicating with 6 other
ISeries
through DDM files. Yesterday on of those remote systems was returning
errors when trying to communicate with it through DDM.
STRPASTHR was running fine but a simple DSPPFM on a freshly created
DDMF would return error CPF4736, with Sense-code 080F6051.
From the documentation, this sense code means that the security
settings passed were not accepted by the remote system.
We checked the user securty and everything look fine.
We restarted QSNADS on the remote system.
From the local system we did a DSPPFM on the DDMF pointing ot the
remote system and it worked. But the other way around (DSPPFM on
remote
sys to local sys) did not work and we were getting a CPF4734, with the
same sense code. So we restarted QSNADS and QCMN on the local system.
Now we could dsppfm both ways.
Anybody knows what could've happened? We are to return on the
production system tonight and we'd like to avoid this kind of problem.
Thanks!