Yes, MF PTFs will apply on an unattended abnormal, but not of the SI PTFs will apply.
Pete
--
Pete Massiello
iTech Solutions
http://www.itechsol.com
http://www.iInTheCloud.com
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Jeff Crosby
Sent: Thursday, December 27, 2012 10:01 AM
To: Midrange Systems Technical Discussion
Subject: PTF apply after abnormal shutdown
All,
In another thread was my story about the power outage we had last Friday, which resulted in an abnormal shutdown.
I had the entire latest cume PTF set to apply during an IPL which I was going to do over a weekend.
When we brought the system up after the abnormal shutdown, it did not apply PTFs. However, it does look like it applied the LIC PTFs (5770-999) as there are none set to apply. Is this the expected behavior, that these PTFs would still be applied after an abnormal shutdown?
Thanks.
--
Jeff Crosby
VP Information Systems
UniPro FoodService/Dilgard
P.O. Box 13369
Ft. Wayne, IN 46868-3369
260-422-7531
www.dilgardfoods.com
The opinions expressed are my own and not necessarily the opinion of my company. Unless I say so.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at
http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.