Operator error, plain and simple.   :-)
Paul Nelson
Cell 708-670-6978
Office 409-267-4027
nelsonp@xxxxxxxxxxxxx
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Norm Dennis
Sent: Thursday, January 30, 2014 6:25 PM
To: 'Midrange Systems Technical Discussion'
Subject: RE: Anybody here know anything about Mimix?
Oops, apologies, smartphone not so smart. 
 
Norm Dennis 
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of nhdennis@xxxxxxxxxxx
Sent: Friday, 31 January 2014 6:39 AM
To: M.C - Midrange-L
Subject: Re: Anybody here know anything about Mimix?
W
Zach
N
Norm Dennis
Z
----- Reply message -----
From: rob@xxxxxxxxx
To: "Midrange Systems Technical Discussion" <midrange-l@xxxxxxxxxxxx>
Subject: Anybody here know anything about Mimix?
Date: Fri, Jan 31, 2014 05:08
Didn't think about the object locks on the target system.
Normally there shouldn't be any.  When we do our backups on the target
system we do quiesce Mimix and restart it upon completion, and time audits
accordingly.
We also do not do queries on our target system.  Although I hear that's a
popular option.  Get some processor utilization out of your target system by
making it your read only query beast.
Hard to figure out what else could be doing the locking.
Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail
to:  2505 Dekko Drive
          Garrett, IN 46738
Ship to:  Dock 108
          6928N 400E
          Kendallville, IN 46755
http://www.dekko.com
From:   AHoerle@xxxxxxxxxxxxx
To:     Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
Date:   01/30/2014 03:47 PM
Subject:        Re: Anybody here know anything about Mimix?
Sent by:        midrange-l-bounces@xxxxxxxxxxxx
   I have seen similar issues in our MIMIX environment if there is a job 
on
   the target system trying to place a lock on the file.  MIMIX wants and
   expects exclusive locks on all of the objects it replicates.  If it is
   another job competing for the file, clearing object locks and running 
the
   audit again at a different time should allow the audit to run
   successfully.
   I second Rob on staying current and contacting Vision support.  They 
have
   been very helpful when I have faced similar issues.
   Good luck!
   Amy Hoerle
   System Administrator
   Think Mutual Bank
   5200 Members Pkwy NW, Box 5949
   Rochester, MN 55901
   507-536-5815 or
   800-288-3425  Ext 5815
   ahoerle@xxxxxxxxxxxxx
   From:        rob@xxxxxxxxx
   To:        Midrange Systems Technical Discussion 
<midrange-l@xxxxxxxxxxxx>
   Date:        01/30/2014 02:03 PM
   Subject:        Re: Anybody here know anything about Mimix?
   Sent by:        midrange-l-bounces@xxxxxxxxxxxx
 
--------------------------------------------------------------------------
   We use Mimix to replicate data from our 'Primary' box to our 
'Secondary'
   box.  We perform our backups nightly on the Secondary box.  Once a 
quarter
   we do a 'switch' from our primary to our secondary to test fail over 
and
   run over the weekend on that.
   What level of Mimix are they on?
   LAKEVIEW/WRKPRD
   We stay pretty current and that command returns:
                                   Installation     Installed
   Product                            Library        Version
   License Manager                   LAKEVIEW        7.1.19.00
   MIMIX Professional                MIMIX           7.1.19.00
   What level of the OS are they on on their source system?
   What level of the OS are they on on their target system?
   Is WRKPTFGRP current on their source system?
   Is WRKPTFGRP current on their target system?
   I ran this command:
   WRKAUD
   and I see a pletora of audits.  Ours are all clean right now...
   Audit       Audit       ---------Definition---------  Object  Objects
   Status      Rule        DG Name    System 1 System 2  Diff    Selected
   *NODIFF     #FILDTA     BPCS_GDI   GDIHQ    GDIHQ2         0    *PTY
   *NODIFF     #IFSATR     BPCS_GDI   GDIHQ    GDIHQ2         0    *PTY
   *NODIFF     #MBRRCDCNT  BPCS_GDI   GDIHQ    GDIHQ2         0    *PTY
   *NODIFF     #OBJATR     BPCS_GDI   GDIHQ    GDIHQ2         0    *PTY
   *NODIFF     #DGFE       IFS        GDIHQ    GDIHQ2         0    *ALL
   *NODIFF     #DLOATR     IFS        GDIHQ    GDIHQ2         0    *PTY
   *NODIFF     #FILATR     IFS        GDIHQ    GDIHQ2         0    *PTY
   *NODIFF     #FILATRMBR  IFS        GDIHQ    GDIHQ2         0    *PTY
   *NODIFF     #FILDTA     IFS        GDIHQ    GDIHQ2         0    *PTY
   *NODIFF     #IFSATR     IFS        GDIHQ    GDIHQ2         0    *PTY
 More...
   But let's look at the *OBJATR audit.  So I'll use "14=Audited objects" 
on
   it.
   Audited            Object
   Status   Type      Name
   *EQ     *DTAQ     DGECAMF/AGAL184002
   *EQ     *DTAQ     DGECAMF/AGAL184032
   *EQ     *DTAQ     DGECAMF/AGAL184111
   There may be options in there to ask it why does it think it's not 
equal.
   It might be easier to check if I had some that were out of sync.
   The reason that I asked about the levels of Mimix, OS and PTF's is that
   often a problem can be resolved by keeping current.
   Take this wild example, some obscure thing changes an attribute on the
   object on their source system.  This attribute change is not recorded 
in a
   file journal entry against the object.  It's also not recorded as an
   object audit entry change in the system object audit journal.  Odd, but
   perhaps possible in a system which believes "if it ain't broke don't 
fix
   it" and has fallen behind on OS and PTFs.
   On a related note, does your join span libraries?  Maybe one of the 
tables
   is in a library that is not 'mimixed' over to the target.  When it 
tries
   to add the member it can't.
   Anyone running Mimix had better be under Mimix support.  They should
   easily tell you what attribute on that object is being flagged and give
   you some suggestions as to what to do to resolve the situation.
   Rob Berendt
   --
   IBM Certified System Administrator - IBM i 6.1
   Group Dekko
   Dept 1600
   Mail to:  2505 Dekko Drive
            Garrett, IN 46738
   Ship to:  Dock 108
            6928N 400E
            Kendallville, IN 46755
   [1]
http://www.dekko.com
   From:   "James H. H. Lampert" <jamesl@xxxxxxxxxxxxxxxxx>
   To:     Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
   Date:   01/30/2014 01:38 PM
   Subject:        Anybody here know anything about Mimix?
   Sent by:        midrange-l-bounces@xxxxxxxxxxxx
   We have a situation at a customer, with an SQL View that's part of our
   Wintouch product, and Mimix.
   I know I've heard of Mimix, but I can't remember what it is, or what it
   does.
   All I know about the problem is what they're telling us:
   > This is the file that gives mimix heartburn every night. I can delete
   > it on ***B*** and push a fresh copy down and the audit runs clean. 
The
   > next day the same thing. I just can***t figure out why*********
   and a screen shot of "Work with Audited Objects," showing (the names
   have been changed to protect the innocent):
   >       Audited             Object
   > Opt   Status    Type      Name
   >  _    *NE       *FILE     WTFOOBAR/WTACTSV2U
   >  _    *EQ       *FILE     WTFOOBAR/WTACTCV1
   >  _    *EQ       *FILE     WTFOOBAR/WTACTSV1
   >  _    *EQ       *FILE     WTFOOBAR/WTACTSV2C
   >  _    *EQ       *FILE     WTFOOBAR/WTADDRV1
   and so forth.
   and it's WTACTSV2U and its *NE status that they're referring to.
   All of the files listed on the screenshot are SQL Views of DDS PFs.
   WTACTSV2U in particular is a UNION ALL of three slightly different
   joins, tying scheduled activities to their accounts and/or contacts, 
and
   WTACTSV2C is a very simple view (I don't even remember why it's
   necessary) that's defined as "SELECT * FROM WTACTSV2U."
   If I understood what MIMIX does, and what the "Work with Audited
   Objects" is trying to tell us, I'd know what to tell the customer.
   --
   JHHL
   --
   This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
   list
   To post a message email: MIDRANGE-L@xxxxxxxxxxxx
   To subscribe, unsubscribe, or change list options,
   visit: [2]
http://lists.midrange.com/mailman/listinfo/midrange-l
   or email: MIDRANGE-L-request@xxxxxxxxxxxx
   Before posting, please take a moment to review the archives
   at [3]
http://archive.midrange.com/midrange-l.
   --
   This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
   list
   To post a message email: MIDRANGE-L@xxxxxxxxxxxx
   To subscribe, unsubscribe, or change list options,
   visit: [4]
http://lists.midrange.com/mailman/listinfo/midrange-l
   or email: MIDRANGE-L-request@xxxxxxxxxxxx
   Before posting, please take a moment to review the archives
   at [5]
http://archive.midrange.com/midrange-l.
References
   Visible links
   1. 
http://www.dekko.com/
   2. 
http://lists.midrange.com/mailman/listinfo/midrange-l
   3. 
http://archive.midrange.com/midrange-l
   4. 
http://lists.midrange.com/mailman/listinfo/midrange-l
   5. 
http://archive.midrange.com/midrange-l
As an Amazon Associate we earn from qualifying purchases.