On 14-Apr-2014 13:08 -0500, J Franz wrote:
We have used a MS linked server for a number of years. After
updating development from V6R1 to V7R1, some of the basic functions
sometimes don't work - getting message "...[filename] contains no
columns that can be selected ...".
This works for a few files, but most do not (have noticed new files
since upgrade have worked, but not verified always true).
<<SNIP>>
The described symptom suggests the data for the columns [that existed
on the system on the prior release] may be missing since the upgrade;
i.e. as a side effect of a condition likely experienced during the
upgrade. That would be the effect, whenever the message CPF32D1 for the
file QADBIFLD in QSYS had been logged. That message is sent to QSYSOPR,
thus would appear in the history; DSPLOG QHST ((*AVAIL) (*BEGIN))
MSGID(CPF32D1). The joblog for the job issuing that message should be
reviewed for the error condition as origin; if the SCPF job, then
WRKSPLF SELECT(QSYS *ALL *ALL SCPF *ALL) to find the joblog(s), because
the job number 000000 is only valid during that IPL. Irrespective the
origin, the likely recovery is via one of the following requests, after
verifying there is no looping conditions of "help me I've fallen, and I
can not get up [most likely cpf32a3 or cpf32a4]" being logged from
either the QDBSRVXR or QDBSRVXR2 jobs [visible in either *SYSOPR or
QHST]: RCLSTG SELECT(*ALL) OMIT(*NONE) or RCLSTG SELECT(*DBXREF)
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact