Paul,
Do a GO LICPGM option 10 on each machine and see if both machines have the same LPPs installed. If box 2 has an additional LPP installed that isn't on box one, you would probably get this.
Pete
--
Pete Massiello
iTech Solutions
http://www.itechsol.com
http://www.iInTheCloud.com
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Paul Nelson
Sent: Monday, December 29, 2014 8:54 AM
To: 'Midrange Systems Technical Discussion'
Subject: TR9 troubles
Picture this:
2 machines sitting almost side by side.
The latest cumulative PTF and the other associated fixes are downloaded from IBM's FTP site to box number 1.
On 12/24, the cume was applied to box 1, the machine was rebooted.
The other fixes were applied, and the box was rebooted again.
WRKPTFGRP showed everything in a status of installed.
The same images were then ftp'd to box 2.
On 12/27, the cume was applied to box 2, and the machine was rebooted.
The other fixes were applied, and the box was rebooted again.
On box 2, SF99709, SF99705, and a couple others show a status of not installed.
These 2 machines have been kept in synch like this for the past 4 years without incident. The archives don't show much about TR9 issues, except for performance problems. I'll be calling IBM today.
Thanks
Paul Nelson
Cell 708-670-6978
Office 409-267-4027
nelsonp@xxxxxxxxxxxxx
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at
http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.