Do you have it cabled correctly.
Stand behind the 5886 and look at the cable. The X cable has 4 ends. One end goes into the two IOAs (same length), and the other two ends that make the "tops" of the X cable, have a short and long end. The short end of the X cable should be on the right side, and the long end of the Y should be left side. If you don't have this correct, it will cause a problem. Now think of the 5886 as two halves, and both those cables should be plugged into the right most side of each of the 5886 sides.
Pete
Pete Massiello
iTech Solutions
http://www.itechsol.com
http://www.iInTheCloud.com
Office: 203-744-7854
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Holger Scherer
Sent: Sunday, June 21, 2015 6:52 AM
To: Midrange Systems Technical Discussion
Subject: Power7 57B58150
Hello all,
a newly installed Power7 box wit 2*TriPort SAS Controller attached to
2*5886 shows this error, maybe due to not installed AA cable. Anyone knows how to reset the DEGRADED state? Loading thousands of PTFs did not solve yet, Hw Support still searching for solution.
Anyone had the same error?
-h
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at
http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.