Le 28/02/2016 13:40, Hoteltravelfundotcom a écrit :
Cause . . . . . : Expected labels not found during end of file processing
for file QSYSTAP in library QSYS on device TAP01.

This is probably due to a previous backup error on the same tape. The last file on the tape is not properly closed with the EndOfFile label, and therefore (the last file) cannot be used. This error also prevents the tape to receive further files.
Normally, you should be able to read the tape up to the not complete last file.
If you want to use this tape for writing, you have to force writing something in place of the not complete last file. Make sure to retrieve its sequence number and run a save command with a small quantity of data (for example SAVLIB LIB(QTEMP)) and with the proper sequence number. This will clear the last file error, so that you can further use SEQNBR(*END).

As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].