Last night I applied V7R1 Test PTF MF61265, on both Production and R&D LPARs.
I previously applied to sandbox LPAR, no issues.

Following the immediate PTF apply

1) not all APPC controllers would vary on.
2) Current session was hung and I could not start any new sessions.
3) HMC console would not connect.

Open PMR with IBM, logs being reviewed.

I had to force power down both LPARs from HMC, which resulted in a few damaged objects and some index path rebuilds.
From the HMC, I used Restart option 2
Operating System - Issue the operating system command to shut donw and restart the logical partition normally.

Was there a better choice that may have prevented the damaged objects and/or idx rebuilds?

Thank You
_____
Paul Steinmetz
IBM i Systems Administrator

Pencor Services, Inc.
462 Delaware Ave
Palmerton Pa 18071

610-826-9117 work
610-826-9188 fax
610-349-0913 cell
610-377-6012 home

psteinmetz@xxxxxxxxxx<mailto:psteinmetz@xxxxxxxxxx>
http://www.pencor.com/


As an Amazon Associate we earn from qualifying purchases.

This thread ...


Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].