I found that the date/timestamps for these are close to matching, same day, time off by a bit.
Are these related, or coincidence?
On my Pencor05 LPAR
Object      Type      Library     Attribute   Text            
P061        *NWSD     QSYS        *GUEST      Pencor06 vSCSI 1
P062        *NWSD     QSYS        *GUEST      Pencor06 vSCSI 2
P063        *NWSD     QSYS        *GUEST      Pencor06 vSCSI 3
P064        *NWSD     QSYS        *GUEST      Pencor06 vSCSI 4
P065        *NWSD     QSYS        *GUEST      Pencor06 vSCSI 5
On my Pencor06 LPAR that was throwing the OPT1481 error.
OPT02       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
OPT03       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
OPT04       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
OPT05       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
OPT06       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
OPT07       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
OPT08       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
OPT09       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
OPT10       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
OPT11       *DEVD     QSYS        OPT         CREATED BY AUTO-CONFIGURATI
Paul
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Rob Berendt
Sent: Thursday, September 29, 2016 4:06 PM
To: Midrange Systems Technical Discussion
Subject: Re: OPT1481 - Add optical disk cartridge failed to complete successfully
WRKHDWRSC *STG
and see if you can find them there.
Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail to:  2505 Dekko Drive
          Garrett, IN 46738
Ship to:  Dock 108
          6928N 400E
          Kendallville, IN 46755
http://www.dekko.com
From:   DrFranken <midrange@xxxxxxxxxxxx>
To:     Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
Date:   09/29/2016 03:47 PM
Subject:        Re: OPT1481 - Add optical disk cartridge failed to 
complete        successfully
Sent by:        "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>
Well Frankie had that many when the SCSI address on the Optical drive 
was set incorrectly. Sadly they all were the same PHYSICAL drive so 
insering a disk and closing the drawer caused that media to appear in 
every drive. It then ejected immediately because all but one were 
duplicates.
So I might surmise that you have an optical drive problem here. Can you 
look at them to see if they have the same serial numbers by chance?
         - Larry "DrFranken" Bolhuis
www.Frankeni.com
www.iDevCloud.com - Personal Development IBM i timeshare service.
www.iInTheCloud.com - Commercial IBM i Cloud Hosting.
On 9/29/2016 3:05 PM, Steinmetz, Paul wrote:
Receiving hundreds of OPT1481 - Add optical disk cartridge failed to 
complete  successfully
For devices OPT01 thru OPT11.
Recovery  . . . :   Ensure that optical device OPT02 is varied on and 
try the
  request again. You may need to eject the cartridge and re-load it.
What is causing this?
How do I resolve?
I don't have this many OPT devices.
What created these.
OPTVRT01          ACTIVE
OPT01             VARIED OFF
OPT02             ACTIVE
OPT03             ACTIVE
OPT04             ACTIVE
OPT05             ACTIVE
OPT06             ACTIVE
OPT07             ACTIVE
OPT08             ACTIVE
OPT09             ACTIVE
OPT10             ACTIVE
OPT11             ACTIVE
Thank You
_____
Paul Steinmetz
IBM i Systems Administrator
Pencor Services, Inc.
462 Delaware Ave
Palmerton Pa 18071
610-826-9117 work
610-826-9188 fax
610-349-0913 cell
610-377-6012 home
psteinmetz@xxxxxxxxxx<mailto:psteinmetz@xxxxxxxxxx>
http://www.pencor.com/
As an Amazon Associate we earn from qualifying purchases.