I found that the date/timestamps for these are close to matching, same day, time off by a bit.
Are these related, or coincidence?
On my Pencor05 LPAR
Object Type Library Attribute Text
P061 *NWSD QSYS *GUEST Pencor06 vSCSI 1
P062 *NWSD QSYS *GUEST Pencor06 vSCSI 2
P063 *NWSD QSYS *GUEST Pencor06 vSCSI 3
P064 *NWSD QSYS *GUEST Pencor06 vSCSI 4
P065 *NWSD QSYS *GUEST Pencor06 vSCSI 5
On my Pencor06 LPAR that was throwing the OPT1481 error.
OPT02 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
OPT03 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
OPT04 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
OPT05 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
OPT06 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
OPT07 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
OPT08 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
OPT09 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
OPT10 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
OPT11 *DEVD QSYS OPT CREATED BY AUTO-CONFIGURATI
Paul
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Rob Berendt
Sent: Thursday, September 29, 2016 4:06 PM
To: Midrange Systems Technical Discussion
Subject: Re: OPT1481 - Add optical disk cartridge failed to complete successfully
WRKHDWRSC *STG
and see if you can find them there.
Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
From: DrFranken <midrange@xxxxxxxxxxxx>
To: Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
Date: 09/29/2016 03:47 PM
Subject: Re: OPT1481 - Add optical disk cartridge failed to
complete successfully
Sent by: "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>
Well Frankie had that many when the SCSI address on the Optical drive
was set incorrectly. Sadly they all were the same PHYSICAL drive so
insering a disk and closing the drawer caused that media to appear in
every drive. It then ejected immediately because all but one were
duplicates.
So I might surmise that you have an optical drive problem here. Can you
look at them to see if they have the same serial numbers by chance?
- Larry "DrFranken" Bolhuis
www.Frankeni.com
www.iDevCloud.com - Personal Development IBM i timeshare service.
www.iInTheCloud.com - Commercial IBM i Cloud Hosting.
On 9/29/2016 3:05 PM, Steinmetz, Paul wrote:
Receiving hundreds of OPT1481 - Add optical disk cartridge failed to
complete successfully
For devices OPT01 thru OPT11.
Recovery . . . : Ensure that optical device OPT02 is varied on and
try the
request again. You may need to eject the cartridge and re-load it.
What is causing this?
How do I resolve?
I don't have this many OPT devices.
What created these.
OPTVRT01 ACTIVE
OPT01 VARIED OFF
OPT02 ACTIVE
OPT03 ACTIVE
OPT04 ACTIVE
OPT05 ACTIVE
OPT06 ACTIVE
OPT07 ACTIVE
OPT08 ACTIVE
OPT09 ACTIVE
OPT10 ACTIVE
OPT11 ACTIVE
Thank You
_____
Paul Steinmetz
IBM i Systems Administrator
Pencor Services, Inc.
462 Delaware Ave
Palmerton Pa 18071
610-826-9117 work
610-826-9188 fax
610-349-0913 cell
610-377-6012 home
psteinmetz@xxxxxxxxxx<mailto:psteinmetz@xxxxxxxxxx>
http://www.pencor.com/
As an Amazon Associate we earn from qualifying purchases.