Rob,
Nope, I checked that.
If server and client both checked, that could explain the 2nd instance.
Paul
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Rob Berendt
Sent: Wednesday, July 26, 2017 3:59 PM
To: Midrange Systems Technical Discussion
Subject: RE: TCP9106 - No response received from NTP server since 7/6 IPL - (2) QTOTNTP server jobs active causing the issue
Do you, by chance, have both the client, and the server, configured to start at IPL?
I suspect more people have just the client start and do not use their IBM i as a time server.
Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail to:  2505 Dekko Drive
          Garrett, IN 46738
Ship to:  Dock 108
          6928N 400E
          Kendallville, IN 46755
http://www.dekko.com
From:   "Steinmetz, Paul" <PSteinmetz@xxxxxxxxxx>
To:     "'Midrange Systems Technical Discussion'" 
<midrange-l@xxxxxxxxxxxx>
Date:   07/26/2017 02:38 PM
Subject:        RE: TCP9106 - No response received from NTP server since 
7/6 IPL -       (2)     QTOTNTP server jobs active causing the issue
Sent by:        "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>
Rob,
They were both started during the IPL process, set to start when TCP/IP 
starts.
Job 879597/QNTP/QTOTNTP started on 07/06/17 at 00:33:12 in subsystem 
QSYSWRK
Job 879598/QNTP/QTOTNTP started on 07/06/17 at 00:33:12 in subsystem 
QSYSWRK
Paul
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Rob 
Berendt
Sent: Tuesday, July 25, 2017 5:57 PM
To: Midrange Systems Technical Discussion
Subject: Re: TCP9106 - No response received from NTP server since 7/6 IPL 
- (2) QTOTNTP server jobs active causing the issue
If the jobs still exist then I would check both of their joblogs to see if 
they started the same way.
If they do not exist then you're down to DSPLOG for that job.
TCP has changed how many things autostart.  For example an autostart job 
entry on one subsystem to another autostart job entry on another 
subsystem.  If you are in the habit of restoring a subsystem from backup 
after an upgrade that could have some stuff start from multiple places.
For example VERY EARLY on in (like back on AS/400's) we used to do this 
for fear of an upgrade removing our hundreds of job queue entries on a 
subsystem description.  However IBM does a good job of not losing these 
during an upgrade.  But, if you've been doing so for so long that the 
subsystem description goes back to V1 or V2 then it cannot update the 
subsystem description during an upgrade (there's some little attribute 
there which puts a halt to it).  We had to recreate it and stop restoring 
it after an upgrade and it's no longer been a concern.
Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail 
to:  2505 Dekko Drive
          Garrett, IN 46738
Ship to:  Dock 108
          6928N 400E
          Kendallville, IN 46755
http://www.dekko.com
From:   "Steinmetz, Paul" <PSteinmetz@xxxxxxxxxx>
To:     "'midrange-l@xxxxxxxxxxxx'" <midrange-l@xxxxxxxxxxxx>
Date:   07/25/2017 03:40 PM
Subject:        TCP9106 - No response received from NTP server since 7/6 
IPL - (2)       QTOTNTP server jobs active causing the issue
Sent by:        "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>
V7R1, Latest CUM and groups.
TCP9106 - No response received from NTP server has been occurring every  3 
to 4 hours since 7/6 IPL.
The SNTP (Simple Network Time Protocol Service) is running.
This is only occurring on Production LPAR. 
R&D LPAR is fine.
Both LPARS configured equally, both pointed to same remote systems.
Remote system  . . . . . . . . .   'us.pool.ntp.org' 
 
               + for more values   '198.60.73.8' 
When checking the Production LPAR, I found that there were (2) QTOTNTP 
server jobs active.
I stopped both, started one new  QTOTNTP server job.
Issue resolved.
Why would an IPL have started (2) QTOTNTP server jobs?
Any thoughts from the group.
Thank You
_____
Paul Steinmetz 
IBM i Systems Administrator 
Pencor Services, Inc. 
462 Delaware Ave 
Palmerton Pa 18071 
610-826-9117 work 
610-826-9188 fax 
610-349-0913 cell 
610-377-6012 home 
psteinmetz@xxxxxxxxxx 
http://www.pencor.com/