OK, I think I've found it:
From iSystems Navigator (or whatever name it goes under now) I went to:
BRMS > Global policy Properties > Network > Manage Systems
The option for "Remote Receives" was set to "No" on the test LPAR, but "Yes" on the development. Changed to "Yes" and I will test again on Monday.
Thanks for the replies Rob & Paul.
--
From: Ian Edmonds
Sent: 29 June 2018 12:47
To: 'midrange-l@xxxxxxxxxxxx' <midrange-l@xxxxxxxxxxxx>
Subject: Restoring a parallel save over BRMS Networking.
Bit of an odd one, we have BRMS and the network feature installed. We also have 3 LPARs and see the media information correctly over all three.
The issue I'm having is that on the main LPAR we save using a parallel save. Restoring individual libraries on one LPAR (development) works fine, but restoring on the third LPAR (test) does not. I keep getting the error "Saved item not found". I know I'm missing something but can't think what it is. Does anyone have any thoughts on this? Note: I can restore on the test LPAR from saves that was not done on a parallel save.
--
________________________________
McColl's Retail Group, McColl's House, Ashwells Road, Brentwood, Essex CM15 9ST
This e-mail including any attachments is intended only for the addressee named above and it may contain confidential or privileged information. If you are not the intended recipient please notify the sender and note that the contents must not be disclosed to anyone else, no copies can be taken and all existing copies must be destroyed. McColl's Retail Group will not be liable for any error in transmission. You should carry out your own virus checks before opening any attachments. Opinions, conclusions and other information in this message and attachments that do not relate to the official business of McColl's Retail Group are neither given nor endorsed by it.
As an Amazon Associate we earn from qualifying purchases.