I always like use an indicator variable for inifinite loops:
D Done s n inz(*off)
/free
DOU Done;
//Do Stuff
ENDDO;
/end-free
Then I use LEAVE to get out and never touch Done. This way you don't have to
worry about the upper limits of *HIVAL nor do you waste cycles comparing 1 to 1.
----- Original Message -----
From: Lim Hock-Chai
To: RPG programming on the AS400 / iSeries
Sent: Thursday, September 14, 2006 2:26 PM
Subject: infinite loop
In fix format, I use to do below for infinite loop
C do *hival
is there a way to do this similar syntax in free format with declare a
variable?
--
This is the RPG programming on the AS400 / iSeries (RPG400-L) mailing list
To post a message email: RPG400-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/rpg400-l
or email: RPG400-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/rpg400-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].