On 2015-03-19 09:41, Steve Landess wrote:
...
     D*           Spooled file number (set only on spool files)
     D  FISPNO               123    124B 0
The "Open feedback area for printer" layout shows two subfields for the 
spool number, one a 2-byte binary and one a 4-byte binary. 
http://www-01.ibm.com/support/knowledgecenter/ssw_ibm_i_72/rzalu/rzalureffeedb.htm?lang=en
Both these subfields are reflected in the INFDS. The RPG reference calls 
the subfield at position 123 "SPOOL_NUM_OLD". There's another subfield 
at position 160 called "SPOOL_NUM", defined as a 4-byte integer with the 
comment "6 digit Spool Nbr". 
http://www-01.ibm.com/support/knowledgecenter/ssw_ibm_i_72/rzasd/infdsopnfb.htm. 
Here's the 7.1 version with fixed-form D specs: 
http://www-01.ibm.com/support/knowledgecenter/ssw_ibm_i_71/rzasd/sc092508139.htm%23wq212
As an Amazon Associate we earn from qualifying purchases.
	
 
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact