O.k., that would explain it. Normally, this is how it should work. However, this is not a "normal" program, and the update routine I posted in my last post needs to run before the next EXFMT. I would have expected the RPG Reference to explain that an I/O on the subfile control record was required before a READC would pick something up. - Dan On Wed, May 13, 2015 at 12:44 PM, John R. Smith, Jr. < smith5646midrange@xxxxxxxxx> wrote: > This is correct. You must do some type of I/O on the control record for > the > SFLNSTCHG to trigger. It has been a long time but doing just a write > instead of an EXFMT of the control record might work. > > -----Original Message----- > From: RPG400-L [mailto:rpg400-l-bounces@xxxxxxxxxxxx] On Behalf Of Roche, > Bob > Sent: Wednesday, May 13, 2015 12:40 PM > To: RPG programming on the IBM i (AS/400 and iSeries) > Subject: RE: SFLNXTCHG head-scratcher > > But the READC is already past that record so it won't read it again until > you EXFMT(write/read) the subfile. At least I never got it to work without > doing that. >
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].