Just thinking...

There is already an ON-EXIT RPG opcode in place
Why not have IBM add an ON-ENTRY opcode and be done with it?


Not the same thing. ON-EXIT is at the procedure level -- not at
the service program level. A service program has no entry point so an
ON-ENTRY opcode would have no anchor point at the service program level
either. The entry point for a service procedure is not an entry point for
the service program. In effect, a service program has no executable code.
It is simply a collection of service procedures that can each be
externally referenced for individual execution.


Sincerely,

Dave Clark

As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].