Hello Gad
I am not understanding why you need the Display Attribute of the I/O
fields.
I have no clue how you plan to use RtvDspAtr, or what use such a
function will serve.
It is quite possible to code your our procedure to get this information,
then you can use the procedure as you wish.
You could code a module to do this using a combination of
?DSM?? Read Screen (without waiting for an AID key).? QsnReadScr. (fwiw
Its not a trivial Api but doable.)
This gives you the entire screen data including attributes, it has
Row/Col information.
and
Your program code needs to know what Screen Format you are using.
and
Then you could use the program DSPINFO, it gives you a Multi Occur DS
that is a list of all the fields with Format and Field Names and
locations from the file object.
From this you can obtain a list of all I/O fields and the fields screen
attributes for your selected Screen Format.
Frank
On 20/08/2022 5:31 pm, Gad Miron wrote:
Thanks to all responders.
I have learned a LOT
(including but not limited to a forgotten DSM)
However,
my OP consisted of asking IBM to add BUILT IN
(RtnDspAtr-like) functionality
for EVERY? input/output field in the display.
Thus freeing the programmers to do business related logic.
But, as the subject says, it is 20 years too late.
Gad
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].