Hi, Simon. At the moment I may answer first question only.
Try this program:
** -------------------------------------------------------------------
Identification Division.
Program-Id. UArgc.
* ------------------------------------------------------
* Compile as CBLLE and run this way:
* Call Uargc
* Call Uargc parm('1')
* Call Uargc parm('1' '2')
* ------------------------------------------------------
Data Division.
Working-Storage Section.
01 Wp usage pointer.
01 w-parametri-ok pic 9(3) value zero.
Linkage Section.
01 LParm01 Pic X(10).
01 LParm02 Pic X(10).
Procedure Division Using LParm01
LParm02
UArgcMain.
****
display ' start'
Set Wp to address of LParm01
If Wp not = Null
add 1 to w-parametri-ok
end-if
Set Wp to address of LParm02
If Wp not = Null
add 1 to w-parametri-ok
end-if
If Wp is = Null
display ' n. of parameters passed ' w-parametri-ok
end-if
display ' end '
GoBack.
** -------------------------------------------------------------------
Regards
Domenico Finucci
Fiditalia , Milano, 02- 4301-2494
-----Messaggio originale-----
Da: Simon Coulter [mailto:shc@flybynight.com.au]
Inviato: venerd́ 10 novembre 2000 08.33
A: COBOL400-L@midrange.com; Jon Paris
Oggetto: COBOL and varying argument lists, etc.
Hello,
I have spent a few hours with the manual and example code but haven't been
able to
determine satisfactory answers.
Question 1.
Does COBOL support a mechanism to determine the number of parameters passed
in to the
program or ILE procedure? (Something like *PARMS or %PARMS in RPG IV) I
know COBOL
programs can be called with a varying argument list but how does the program
know how
many parameters it received? I expected a SPECIAL-NAME would be available
but can't find
one. Must I test the parameter comparing the ADDRESS OF to NULL?
Question 2.
I have an RPG procedure in a service program with the following interface:
D getDay PR 5I 0
D aDate D DATFMT(*ISO) CONST OPTIONS(*NOPASS)
I am invoking that procedure from COBOL using the following methods:
call linkage procedure "GETDAY"
returning day-nbr
call linkage procedure "GETDAY"
using a-date
returning day-nbr
Both procedure calls are in the same program and the parameters are defined
thus:
01 a-date FORMAT DATE "@Y-%m-%d".
01 day-nbr pic s9(04) binary.
Would you expect both procedure calls to work assuming that the getDay
procedure
functions correctly?
Question 3.
Would you expect the %PARMS value to be set correctly in getDay after each
of the above
calls? That is:
call linkage procedure "GETDAY"
returning day-nbr
and %PARMS should be zero
call linkage procedure "GETDAY"
using a-date
returning day-nbr
and %PARMS should be one
Question 4.
Not strictly a COBOL question but it strikes me as useful to define the
above RPG
prototype with both *NOPASS and *OMIT options. The nett result is the same
but the
caller can choose the call construct that suits them. Comments?
Regards,
Simon Coulter.
«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»
«» FlyByNight Software AS/400 Technical Specialists «»
«» Eclipse the competition - run your business on an IBM AS/400. «»
«» «»
«» Phone: +61 3 9419 0175 Mobile: +61 0411 091 400 «»
«» Fax: +61 3 9419 0175 mailto: shc@flybynight.com.au «»
«» «»
«» Windoze should not be open at Warp speed. «»
«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»«»
+---
| This is the COBOL/400 Mailing List!
| To submit a new message, send your mail to COBOL400-L@midrange.com.
| To subscribe to this list send email to COBOL400-L-SUB@midrange.com.
| To unsubscribe from this list send email to COBOL400-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator:
david@midrange.com
+---END
+---
| This is the COBOL/400 Mailing List!
| To submit a new message, send your mail to COBOL400-L@midrange.com.
| To subscribe to this list send email to COBOL400-L-SUB@midrange.com.
| To unsubscribe from this list send email to COBOL400-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---END
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.