>Could anyone please let me know what the problem is when you have a >CPF1269 return code 715,0. We are receiving this message when trying to >do passthru from one system to the other. We get it on the receiving >machine. We can passthru one way but get this error the other way.. For these kinds of errors, I look in the Asynchronous Communications Programming Guide (at least that is what it was called the last time I looked at appendix B) A "715" says that "No user ID or Password was supplied, and no default user ID was specified in the communications entry." Check your communications subsystem's communication entries; see if you have a default user ID in there... Buck Calabro Commsoft, Rensselaer, NY +--- | This is the Midrange System Mailing List! | To submit a new message, send your mail to "MIDRANGE-L@midrange.com". | To unsubscribe from this list send email to MAJORDOMO@midrange.com | and specify 'unsubscribe MIDRANGE-L' in the body of your message. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].