|
This is really weird.The devices that I have substituted in are consoles from other systems ( I have an 800 and an 720). So the addresses are set at 0. All three consoles work on the 800 and the 720. I even swapped and tested all three cables which work on the 800 and 720. However, when I connect them to the 170 I get nothing. It will autoconfig a 3476 device and the status goes to vary on pending but the device itself never becomes active. I tried deleting the device several times and I tried other addresses just to see if it is a "console" thing. I varied the controller off, deleted the device and then varied the controller on. I get a device description created, no signon screen.
The alternate brick was an attempt to isolate a possible hardware issue but that brick works on the 720 and is identical to the original on the 170 but made no difference. I am down to a possible card problem but the 170 isn't reporting any hardware problems at all.
Strange, very strange. Pete Jim Franz wrote:
I know you must have each of the 3 devices you tried at port 0, addr 0 and you really did cable to port 0 of the 1st twinax controller on the 170? Have you (once connected) powered of device then on? Then, if not working, is device "type" same on each test device? Is possible the subsystem has workstn entry for diff dev type? Go cmdhdw does show the twinax adapter resource is up & ready? Can it be varied off/on? <grasping for straws> jim franz----- Original Message ----- From: "Pete Helgren" <Pete@xxxxxxxxxx>To: "Midrange Mailing List" <MIDRANGE-L@xxxxxxxxxxxx> Sent: Friday, March 31, 2006 10:50 PM Subject: Twinax console refuses to give signon screenI am stumped with this one. I have a 170 that I usually have a console connected to but the thing is bulky and takes up space so I unplugged it and put it away. Now that I need it, I can't get the thing to give me a signon screen. I tried 3 different terminals. Three different twinax cables and even a different 4 port "brick" I borrowed from another machine. No joy. I can delete DSP01 and it will autoconfig another one (at address 0 port 0 on the correct controller) but the cursor just hangs on the right hand side of the screen. No signon. I *think* I have ruled out a hardware problem. There are no messages. No SRC's. Nuthin'. It has to be a configuration issue but I sure can't think of anything I might have missed. Any ideas? Thanks, Pete Helgren --This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing listTo post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/mailman/listinfo/midrange-l or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.