Rob,

Thanks for your answer. 

I think I have found the answer. Have to "switch" the server from the "P" 
(Permanent) side to the "T" (temporary) side, using the control panel, and THEN 
do the IPL. 

Will try it tomorrow and keep you posted. 

Regards,

Luis Rodriguez



midrange-l-request@xxxxxxxxxxxx wrote:
------------------------------

message: 9
date: Tue, 27 Mar 2007 16:15:10 -0400
from: rob@xxxxxxxxx
subject: Re: Server IPL on a non-HMC system

Granted I work on an HMC controlled system.

In my environment a PWRDWNSYS *IMMED RESTART(*NO) does not power down the 
whole frame - just a particular lpar.  So a PWRDWNSYS *IMMED RESTART(*YES) 
would not qualify as a "server IPL".  I'd have to IPL the whole frame and 
not just a particular lpar.  Now, just because you don't have a hmc 
doesn't mean your machine is still not thinking lpar.  After all, you can 
have 1 i5/os lpar and a number of linux lpar's and still be a non hmc 
controlled system.  Although I am not sure how one controls the whole 
server without an HMC - maybe with ASMI?

Rob Berendt

As an Amazon Associate we earn from qualifying purchases.

This thread ...


Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].