Hadn't thought about that, Doug. Only works in a CL, of course, if there
isn't a higher level OCL procedure. But if that's the case, I could plug it
in the higher OCL. I've gotten bit on the rump before with an OCL calling a
CL that then tried to run the STRS36PRC command.
Jerry C. Adams
IBM i Programmer/Analyst
Why is the world so full of old cynics? Cynics live longer.
--
A&K Wholesale
Murfreesboro, TN
615-867-5070
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Douglas Handy
Sent: Tuesday, September 13, 2011 12:41 PM
To: Midrange Systems Technical Discussion
Subject: Re: 36EE Files Library Determination
If nothing else, you could call STRS36PRC and call a procedure which
contained something like:
// LOCAL OFFSET-?1'501'?,BLANK-10,DATA-'?FLIB?'
then read it back out of the *LDA when you are done. You could pass in the
starting LDA position, which defaults to 501 above. Not as nice as an API,
but gets the job done without assumptions.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact