In the normal backup that is run, we use the STRBKUBRM but I couldn't run
the normal backup to test as it shuts down all the subsystems. We use BRMS
for all backups here whether it is virtual or actual tape.

Thanks again
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of
rob@xxxxxxxxx
Sent: Friday, February 13, 2015 8:18 AM
To: Midrange Systems Technical Discussion
Subject: RE: tape cartridge categories

Yes, normally you don't use the SAVLIBBRM commands. You should be using
STRBKUBRM. That will use a 'control group'. And that control group will
have a policy set with it that will contain things like expiration date,
move policy, etc. With the move policy handling things like putting things
on the PRTMOVBRM so if one of your locations is, say, IRONMTN, it will then
be flagged on that report to be moved to Iron Mountain. And the expired
tapes will be on the report to be recalled from Iron Mountain. I don't mess
with putting a date to ship back on Iron Mountain's website. I use this
BRMS report to know which ones to order back.


Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail
to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com





From: "Dave W" <ldwopt@xxxxxxx>
To: "'Midrange Systems Technical Discussion'"
<midrange-l@xxxxxxxxxxxx>
Date: 02/13/2015 08:51 AM
Subject: RE: tape cartridge categories
Sent by: "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>



Rob and all

I was not feeling well yesterday and was not thinking clearly. I woke up
at
2:30 am and was laying in bed mulling things over and realized what I had
used for a command.

Yes we use BRMS so this morning SAVLIBBRM and it all worked fine. The only
thing I am concerned about is that I used *SYSPCY for media policy and on
the normal backup a special media policy is specified. Will do more
checking on that this morning

Thank you all for helping with your suggestions

Dave Willenborg
FNTS


-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of
rob@xxxxxxxxx
Sent: Friday, February 13, 2015 7:26 AM
To: Midrange Systems Technical Discussion
Subject: Re: tape cartridge categories

Well, since you've tried the command WRKMLMBRM I am going under the
assumption that you have BRMS. BRMS is all about the volume id.

I have not used DSPTAPCGY since I started using BRMS. There are a lot of
those type of commands I have written down when we first went to tape
libraries but didn't use BRMS.

Just to verify that the tape library can read you can try WRKMEDBRM
TYPE(*ACT) LOC(TAPMLB01) Once you find an active tape DSPTAP DEV(TAPMLB01)
VOL(XXXXXX) ENDOPT(*REWIND) replacing the x's by a valid volume id.

You may want to look at the SAVLIBBRM command versus the SAVLIB command
But
if you want to stick with the SAVLIB command instead of using *MOUNTED for
the volume id try entering one of the volume names currently in the
library.

Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail
to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com





From: "Dave W" <ldwopt@xxxxxxx>
To: "'Midrange Systems Technical Discussion'"
<midrange-l@xxxxxxxxxxxx>
Date: 02/13/2015 08:03 AM
Subject: tape cartridge categories
Sent by: "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>



Good morning



I got called into work on this to figure out what is wrong.



We had a tape library go bad and replaced the complete unit. It was varied
off before the swap and after the swap it was varied on. ALL looked ok.



The backup last night aborted so I have been looking at it today. It is
configured as 3580 library with a 3581 tape drive.



When I do a WRKMLMBRM the loaded tapes show the tapes are in *share400
category and one tape is Mounted



When I do WRKMLBSTS is shows the tap library as varied on



It shows the tap01 as operational and unprotected.



IF I do a DSPTAPCGY it shows many categories tied to the Serial number or
system name.



When I try and do a SAVLIB LIBA TAPMLB01 I get a CPF3794 I do an
F10
and it states the *MOUNTED is not correct



I have never worked with cartridge types before. How do I reset or
allocate
the cartridge to the new drive?





Any help would be appreciated



Thanks

Dave Willenborg

FNTS

Omaha NE




As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.