Aaron Bartell wrote:
Is there anything *special* I need to do to have a service entry point
applied to a trigger program? The reason I ask is because my customer
and I (we are on a web meeting right now) have been trying to attach
to a program using every user profile we can think of including both
users in the PSDS data structure (in our case QUSER and MYUSER) of the
actual trigger program (we used DSPLY to get those values).

Not that I'm aware of ... I was able to debug trigger programs using SEP without a problem. I was using WDSC 7.0.

Make sure the profile you are attaching with has authority to the program AND the user that's causing the trigger to run.

david


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].