Remember this is the HMC code, you really can't get to Linux directly except
in very special circumstances, and then only with IBMs help. (Access via
ROOT)

If there is a way to control the mouse behavior in HMC code, I've not found
it...... In either classic or the so called Enhanced + interface



--
Jim Oberholtzer
Agile Technology Architects

-----Original Message-----
From: MIDRANGE-L <midrange-l-bounces@xxxxxxxxxxxx> On Behalf Of Musselman,
Paul
Sent: Friday, December 07, 2018 10:31 AM
To: Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
Subject: RE: P9 racking/rail questions/issues

Windows has a speed control in the "mouse" control panel. I'd expect *nix
to have something similar...

I really don't mind the button. It's always 'right there.'

Paul E Musselman
PaulMmn@xxxxxxxxxxxxx

-----Original Message-----
From: MIDRANGE-L <midrange-l-bounces@xxxxxxxxxxxx> On Behalf Of Jim
Oberholtzer
Sent: Friday, December 07, 2018 7:56 AM
To: 'Midrange Systems Technical Discussion' <midrange-l@xxxxxxxxxxxx>
Subject: RE: P9 racking/rail questions/issues

Yea, and the new ones are set up to move way too fast making it really
difficult to control.


--
Jim Oberholtzer
Agile Technology Architects

-----Original Message-----
From: MIDRANGE-L <midrange-l-bounces@xxxxxxxxxxxx> On Behalf Of Steinmetz,
Paul
Sent: Thursday, December 06, 2018 3:59 PM
To: 'Midrange Systems Technical Discussion' <midrange-l@xxxxxxxxxxxx>
Subject: RE: P9 racking/rail questions/issues

Found something else interesting.
The new keyboard for the HMC 7063-CR1 has no mouse pad, only a button.
Yuk.

Paul

-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of
DrFranken
Sent: Thursday, December 06, 2018 4:12 PM
To: Midrange Systems Technical Discussion
Subject: Re: P9 racking/rail questions/issues

EXP24 rails are some of my favorite! Insert and snap on the clip! Unless
they are none IBM racks which introduces the changing of the screws and
potential lenght issues. Still though easy.

The HMC also simple IF you're familiar with Supermicro 1U servers. If not
they they still aren't bad but different.

The flat panels, yeah don't make me tell you about 'Exhibit A' and 'Exhibit
B' screws.....

- Larry "DrFranken" Bolhuis

www.Frankeni.com
www.iDevCloud.com - Personal Development IBM i timeshare service.
www.iInTheCloud.com - Commercial IBM i Cloud Hosting.

On 12/6/2018 3:01 PM, Steinmetz, Paul wrote:
Thanks everyone, we're good.
P9 all racked and cabled.
Rails were a night mare, all different, the documentation was not
totally
accurate.
9009-42A and 7316 Flat panel console rails weren't bad.
Improper screws, (wrong thread size) for attaching Flat Panel to the
flat
panel rails.
EXP24SX storage enclosure and 7063-CR1 rails, that's another story.

On to HMC configuration.
Except for the HMC ip, would be acceptable to mirror the settings from
my
P7 HMC, 7042-CR6?
Let the fun begin.

Paul

-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of
Jim Oberholtzer
Sent: Thursday, December 06, 2018 2:47 PM
To: 'Midrange Systems Technical Discussion'
Subject: RE: P9 racking/rail questions/issues

The P9 is 3/4 inch beyond a P8 or P7 server? If so, then look to see
if you put a screw in the front of the rail BEFORE you pushed in the
server. I'll
bet it's hitting a screw. If it's the same as the P8/P7, that's where
its
supposed to be.

The HMC does not have rails that allow it to be pulled out like the
earlier
HMCs did. There is no provision for that in the rail. Both Steve and
I
alluded to that earlier when we told you there was no cable management
arm for the HMC.


--
Jim Oberholtzer
Agile Technology Architects

-----Original Message-----
From: MIDRANGE-L <midrange-l-bounces@xxxxxxxxxxxx> On Behalf Of
Steinmetz, Paul
Sent: Thursday, December 06, 2018 1:38 PM
To: 'Midrange Systems Technical Discussion' <midrange-l@xxxxxxxxxxxx>
Subject: P9 racking/rail questions/issues

1)The front of the 9009-42A server extends 1/2 to 3/4 inches past any
other device in the rack.
It appears to be mounted correctly and is pushed all the way in.
Is this normal for P9 servers, or do I have a rail/rack issue?

2) When pulling out the HMC, it only extends 1/2 way, not fully like
the 9009-42A.
Is this normal for the 7063-CR1, or do I have a rail/rack issue?
If engaging the release buttons, the HMC then extends further, but
becomes released from the rails.

Thank You
_____
Paul Steinmetz
IBM i Systems Administrator

Pencor Services, Inc.
462 Delaware Ave
Palmerton Pa 18071

610-826-9117 work
610-826-9188 fax
610-349-0913 cell
610-377-6012 home

psteinmetz@xxxxxxxxxx
http://www.pencor.com/

--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe,
or change list options,
visit: https://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a
moment to review the archives at https://archive.midrange.com/midrange-l.

Please contact support@xxxxxxxxxxxx for any subscription related questions.

Help support midrange.com by shopping at amazon.com with our affiliate link:
https://amazon.midrange.com


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.